Metrologic OrbitCG MS7180 Guida Utente

Navigare online o scaricare Guida Utente per Lettori di codici a barre Metrologic OrbitCG MS7180. Metrologic OrbitCG MS7180 User`s guide Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - Presentation Laser Scanner

METROLOGIC INSTRUMENTS, INC. MS7180 OrbitCG® Presentation Laser Scanner Installation and User’s Guide

Pagina 2

6 Figure 5.Figure 7.Figure 6. Figure 8.INTRODUCTION Mounting Specifications Optional Wall/Counter Mount, MLPN 45-45619 Item Description Qty.a.

Pagina 3 - ABLE OF CONTENTS

7INSTALLATION RS232, Light Pen Emulation 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pi

Pagina 4

8 INSTALLATION RS485S 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the MS7180. 3.

Pagina 5

9INSTALLATION Keyboard Wedge 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on th

Pagina 6

10 INSTALLATION Stand-Alone Keyboard 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin sock

Pagina 7

11INSTALLATION Full Speed or Low Speed USB 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB cable into the 10-pin socke

Pagina 8

12 INSTALLATION EAS Deactivation SW1 and SW2 are the switch banks inside the Checkpoint Device that set the deactivation range. The following is

Pagina 9

13SCANNER OPERATION POWER SAVE MODES The OrbitCG has five configurable power save modes. Refer to the MetroSelect Configuration Guide (MLPN 00

Pagina 10 - INTRODUCTION

14 SCANNER OPERATION Primary and Secondary Scan Pattern Modes There are two scan pattern modes available with the MS7180. • The primary scan pa

Pagina 11 - INSTALLATION

15SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE ENABLED 1. The primary (omni) scan pa

Pagina 12

Copyright © 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, tran

Pagina 13

16 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE DISABLED 1. The primary (omni) scan p

Pagina 14

17SCANNER OPERATION Audible Indicators When the MS7180 is in operation, it provides audible feedback to indicate the status of the scanner. Eig

Pagina 15

18 SCANNER OPERATION Visual Indicators The MS7180 is equipped with a blue and a white LED that indicates the scanner’s state and the status of th

Pagina 16

19SCANNER OPERATION Failure Mode Indicators Flashing Blue with One Razzberry Tone This indicates that the scanner has experienced a laser subs

Pagina 17 - POWER SAVE MODES

20 SCANNER OPERATION Depth of Field Specifications* Normal Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. Figure 17. MS71

Pagina 18 - SCANNER OPERATION

21SCANNER OPERATION Depth of Field by Bar Code Element Width* Normal Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F G H J K mm .13

Pagina 19

22 SCANNER OPERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F G H J K mm - .

Pagina 20

23TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3

Pagina 21

24 TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution All Interfaces The unit is trying to scan a particular symbology that is not enabled

Pagina 22

25TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution All Interfaces The bar code may have been printed incorrectly. Check if it is a chec

Pagina 23

iiTABLE OF CONTENTS Introduction Product Overview ... 1 Sc

Pagina 24

26 TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution RS232 Only The host is receiving data but the data does not look correct. The scanne

Pagina 25

27DESIGN SPECIFICATIONS MS7180 Operational Light Source: Visible Laser Diode (VLD) @ 650 nm Laser Power: Less than 1 mW average Normal Depth

Pagina 26

28 DESIGN SPECIFICATIONS MS7180 Electrical Voltage Supply: 5VDC ± 0.25V Operating Power: 0.9 W Standby Power: 0.85 W Blink Power Save Mode

Pagina 27 - TROUBLESHOOTING GUIDE

29APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. SCANNER V

Pagina 28

30 DEFAULT SETTINGS - COMMUNICATION PARAMETERS Many functions of the scanner can be "configured" - that is enabled or disabled. The sca

Pagina 29

31DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT RS232 LIGHT PEN RS485SKBW USB Expanded ID “]e0” *      RSS Limited Enab

Pagina 30

32 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT RS232 LIGHT PEN RS485SKBW USB Transmit UPC-A Check Digit *      Trans

Pagina 31 - DESIGN SPECIFICATIONS

33DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT RS232 LIGHT PEN RS485SKBW USB Nixdorf ID    LRC Enabled    UPC Pr

Pagina 32

34 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT RS232 LIGHT PEN RS485SKBW USB Supplements are not Required *      Two

Pagina 33 - APPLICATIONS AND PROTOCOLS

35SCANNER CONFIGURATION CONFIGURATION MODES The MS7180 Series scanner has three modes of configuration. • Bar Codes The MS7180 can be configure

Pagina 34 - Host applications

iiiTABLE OF CONTENTS Design Specifications ... 27 Applications

Pagina 35

36 UPGRADING THE FIRMWARE The MS7180 is part of Metrologic's line of scanners with flash upgradeable firmware. The upgrade process requires,

Pagina 36

37SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The MS7180 scanner interfaces terminate to a 10-pin modular socket. The serial numbe

Pagina 37

38 SCANNER AND CABLE TERMINATIONS Figure 22. MS7180-120 Full Speed USB with EAS Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive I

Pagina 38

39SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) “Standard” PowerLink Cable MLPN 59-59000x -3 straight Pin Function 1

Pagina 39 - SCANNER CONFIGURATION

40 SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge PowerLink Cable 59-59002x -3 Pin Function 1 Keyboard C

Pagina 40 - UPGRADING THE FIRMWARE

41REGULATORY COMPLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Cau

Pagina 41 - Scanner Pinout Connections

42 REGULATORY COMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 Changes or modifications not expre

Pagina 42 - Figure 22

43REGULATORY COMPLIANCE EMC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s autho

Pagina 43 - MLPN 54-54214

44 LIMITED WARRANTY The MS7180 OrbitCG® scanners are manufactured by Metrologic at its Suzhou, China facility. The MS7180 OrbitCG scanners have a

Pagina 44

45PATENTS Patent Information This METROLOGIC product may be covered by, but not limited to, one or more of the following U.S. Patents: U.S. Pate

Pagina 45 - EGULATORY COMPLIANCE

1INTRODUCTION OrbitCG® is an aggressive, omnidirectional laser bar code scanner ideal for use in retail, convenience, liquor and specialty stores

Pagina 46

46 INDEX A AC ... see power accessories ...2, 3 adapter ...

Pagina 47 - REGULATORY COMPLIANCE

47INDEX O operation ...43 P patents...45 PC ...

Pagina 52

July 2008 Printed in the USA 00-02284B

Pagina 53

2 INTRODUCTION Scanner and Accessories BASIC KIT COMPONENTS Part No. Description MS7180 OrbitCG Presentation Laser Bar Code Scanner 00-02284x MS

Pagina 54

3INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part No. Description 59-59002x-3 Keyboard Wedge PowerLink Cable straight cord 59-590

Pagina 55

4 Figure 2. Cable ReleaseINTRODUCTION Scanner Components ITEM NO DESCRIPTION 1 Mode Select Button/CodeGate Button (see page 14) 2 White LED (se

Pagina 56 - Printed in the USA

5INTRODUCTION Caution and Serial Number Labels Figure 3. Label Location on the Bottom of the Scanner with Example Caution To maintain comp

Commenti su questo manuale

Nessun commento